Table 2

Parameters of myocardial coordination and left ventricular systolic function obtained by tissue Doppler echocardiography.

Variables
Controls N = 20
LBBB N = 21
ICMP N = 19
DCMP N = 26
P

EMDT, ms
14 ± 1
45 ± 4*
42 ± 9*
47 ± 12*
< 0.001
EHDT, ms
81 ± 10
136 ± 10*
136 ± 25*
163 ± 33*†‡
< 0.001
IVCT, ms
67 ± 9
91 ± 8*
96 ± 18*
116 ± 31*†
< 0.001
IVRT, ms
70 ± 10
134 ± 18*
127 ± 34*†
160 ± 29*†‡
<0.001
ET, ms
321 ± 20
278 ± 41*
207 ± 28*†
220 ± 44*†
< 0.001
PSV, cm/s
6.3 ± 1.1
4.1 ± 0.8*
2.6 ± 0.8*†
3.2 ± 1.0*†
< 0.001
A-V, mm
9.7 ± 1.5
8.0 ± 1.8*
3.9 ± 1.6*†
5.6 ± 2.8*†
<0.001

Abbreviations: A-V = Atrio-ventricular plane displacement; EHDT = Electro-hemodynamic delay time; EMDT = Electro-mechanical delay time; ET = Ejection time; IVCT = Isovolumic contraction time; IVRT = Isovolumic relaxation time; PSV = Peak systolic velocity.

P = Analysis of variance.

* < 0.05 vs. Controls.

†< 0.05 vs. LBBB.

‡ < 0.05 vs. ICMP.

Quintana et al. Cardiovascular Ultrasound 2008 6:39   doi:10.1186/1476-7120-6-39