Email updates

Keep up to date with the latest news and content from Cardiovascular Ultrasound and BioMed Central.

Open Access Highly Accessed Research

Midwall ejection fraction for assessing systolic performance of the hypertrophic left ventricle

Hisao Yoshikawa*, Makoto Suzuki, Go Hashimoto, Yukiko Kusunose, Takenori Otsuka, Masato Nakamura and Kaoru Sugi

Author Affiliations

Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi, Meguro-ku, Tokyo, Japan

For all author emails, please log on.

Cardiovascular Ultrasound 2012, 10:45  doi:10.1186/1476-7120-10-45

Published: 20 November 2012

Abstract

Background

In patients with left ventricular hypertrophy (LVH), LV midwall fractional shortening (FS) is used as a measure of LV systolic performance that is more physiologically appropriate than conventional FS. For evaluation of LV volume and ejection fraction (EF), 2-dimensional (2D) echocardiography is more accurate than M-mode echocardiography. The purpose of this study was to assess systolic performance by midwall EF using 2D speckle tracking echocardiography (STE).

Methods

Sixty patients were enrolled in the study. Patients were divided into two groups with LVH (n = 30) and without LVH (control group, n = 30). LV systolic function was compared between the two groups and the relationships of left ventricular mass index (LVMI) with LV systolic parameters, including midwall EF, were investigated.

Results

Midwall EF in the LVH group was significantly lower than that in the control group (42.8±4.4% vs. 48.1±4.1%, p <0.0001). Midwall FS was also significantly lower in the LVH group (13.4±2.8% vs. 16.1±1.5%, p <0.0001), but EF did not differ significantly between the two groups. There were significant correlations between midwall EF and LVMI (r=0.731, p <0.0001) and between midwall FS and LVMI (r=0.693, p <0.0001), with midwall EF having the higher correlation.

Conclusions

These results show that midwall EF can be determined using 2D STE. Midwall EF can be used to monitor LV systolic dysfunction, which is not possible with conventional EF. Evaluation of midwall EF may allow assessment of new parameters of LV systolic function in patients with LV geometric variability.

Keywords:
Midwall ejection fraction; Left ventricular systolic function; Left ventricular hypertrophy; Speckle tracking echocardiography